Gas Regulators, Meters, Valves & Filters
High-quality equipment for gas distribution and control
Gas Regulators, Meters, Valves & Filters: products
No products match the selected filters.
Aperflux 101
Pilot operated regulator for high-medium pressure applications.
- Design Pressure: Up to 85 bar
- Sizes: 2″ - 4″
- Classification: Fail Open (EN 334)
- Connections: 300 RF, 600 RF, RTJ
H2 Ready
Aperflux 851
Pilot operated regulator with hydrogen compatibility.
- Design Pressure: Up to 102 bar
- Sizes: 1″ - 10″
- Classification: Fail Open (EN 334)
- Connections: 150 RF, 300 RF, 600 RF, PN 16, PN 25, PN 40
ASX 176
Pilot operated regulator for industrial applications.
- Design Pressure: Up to 102 bar
- Sizes: 1″ - 6″
- Classification: Fail Close (EN 334)
- Connections: 300 RF, 600 RF, RTJ
ASX 176/FO
Fail-open pilot operated regulator.
- Design Pressure: Up to 102 bar
- Sizes: 1″ - 6″
- Classification: Fail Open (EN 334)
- Connections: 300 RF, 600 RF, RTJ
H2 Ready
Dixi AP
Pilot operated regulator for high pressure networks.
- Design Pressure: Up to 85 bar
- Sizes: 1″
- Classification: Fail Close (EN 334)
- Connections: Class 150, 300, 600 RF or RTJ, PN 16
H2 Ready
Reflux 819
Premium pilot operated regulator with H2 compatibility.
- Design Pressure: Up to 102 bar
- Sizes: 1″ - 12″
- Classification: Fail Close / Fail Open (EN 334)
- Connections: 150 RF, 300 RF, 600 RF, PN 16
H2 Ready
Reflux 819/FO
Fail-open version of the Reflux 819 regulator.
- Design Pressure: Up to 102 bar
- Sizes: 1″ - 12″
- Classification: Fail Open (EN 334)
- Connections: Class 150, 300, 600 RF or RTJ, PN 16
H2 Ready
Terval AP
Pilot operated regulator for high and medium pressure distribution networks.
- Design Pressure: Up to 102 bar
- Sizes: 1″ - 4″
- Classification: Fail Close (EN 334)
- Connections: 300 RF, 600 RF, RTJ
ATF Anti-Freeze
Direct operated regulator for high pressure systems.
- Design Pressure: Up to 220 bar
- Sizes: 1/4″
- Classification: Fail Open (EN 334)
- Connections: NPT
Dival 160 AP
Direct operated regulator for high-medium pressure applications.
- Design Pressure: Up to 85 bar
- Sizes: 1″
- Classification: Fail Open (EN 334)
- Connections: 300 RF, 600 RF, RTJ
FT 518
Direct operated regulator for industrial use.
- Design Pressure: Up to 69.4 bar
- Sizes: 3/4″ - 2″
- Connections: Threaded NPT or flanged
H2 Ready
Norflux
Direct operated regulator for distribution networks.
- Design Pressure: Up to 100 bar
- Sizes: 2″
- Classification: Fail Open (EN 334)
- Connections: Class 300/600 RF/RTJ
Staflux 185
Direct operated regulator for medium pressure.
- Design Pressure: Up to 100 bar
- Sizes: 1″ - 3″
- Classification: Fail Open (EN 334)
- Connections: 300 RF, 600 RF, RTJ
Staflux 187
Direct operated regulator for industrial applications.
- Design Pressure: Up to 250 bar
- Sizes: 1″
- Classification: Fail Open (EN 334)
- Connections: Class 1500 RF or RTJ
H2 Ready
Staflux Mini
Compact direct operated regulator.
- Design Pressure: Up to 250 bar
- Sizes: 1″
- Classification: Fail Close (EN 334)
- Connections: 1500 RF, threaded NPT
H2 Ready
Aperval
Pilot operated regulator for medium-low pressure.
- Design Pressure: Up to 25 bar
- Sizes: 1″ - 4″
- Classification: Fail Open (EN 334)
- Connections: Class 150 RF, PN 16, PN 25
H2 Ready
Aperval 101
Pilot operated regulator for distribution networks.
- Design Pressure: Up to 18.9 bar
- Sizes: 2″ - 4″
- Classification: Fail Open (EN 334)
- Connections: Class 125FF, 125 RF, 150 RF, PN 16
H2 Ready
Dixi
Pilot operated regulator for distribution.
- Design Pressure: Up to 16 bar
- Sizes: 1″ - 2″
- Classification: Fail Close/Open (EN 334)
- Connections: Class 150 RF, PN 16, PN 25
H2 Ready
Reval 182
Pilot operated regulator for medium pressure.
- Design Pressure: Up to 25 bar
- Sizes: 1″ - 10″
- Classification: Fail Close / Fail Open (EN 334)
- Connections: Class 150 RF or RTJ, PN 16/25/40
H2 Ready
Terval/A
Pilot operated regulator for district stations.
- Design Pressure: Up to 25 bar
- Sizes: 2″ - 4″
- Classification: Fail Open (EN 334)
- Connections: Class 150 RF or RTJ, PN 25/40
H2 Ready
Terval/R
Pilot operated regulator for distribution networks.
- Design Pressure: Up to 25 bar
- Sizes: 2″ - 4″
- Classification: Fail Close (EN 334)
- Connections: Class 150 RF or RTJ, PN 25/40
H2 Ready
Cirval
Direct operated regulator for distribution.
- Design Pressure: Up to 8.6 bar
- Sizes: 1-1/4″ - 2″
- Classification: Fail Open (EN 334)
- Connections: Threaded ANSI B1.20.1, ANSI 125FF
H2 Ready
Cirval CE
CE certified direct operated regulator.
- Design Pressure: Up to 8.6 bar
- Sizes: 1-1/2″ - 2″
- Classification: Fail Open (EN 334)
- Connections: Threaded ISO 228-1, PN 16, ANSI 150RF
H2 Ready
Dival 500
Direct operated regulator with H2 compatibility.
- Design Pressure: Up to 20 bar
- Sizes: 1″ x 1″, 1″ x 1-1/2″
- Classification: Fail Open (EN 334)
- Connections: Rp, NPT
H2 Ready
Dival 507-512
Direct operated regulator series for various applications.
- Design Pressure: 10-20 bar (BP/MP/TR)
- Sizes: 1″ - 1-1/2″
- Classification: Fail Open (EN 334)
- Connections: Threaded Rp, NPT
H2 Ready
Dival 600
Direct operated regulator with H2 compatibility.
- Design Pressure: Up to 20 bar
- Sizes: 1″ - 2″
- Classification: Fail Open (EN 334)
- Connections: Class 150 RF, ANSI 125 FF, PN 16/25, Threaded
H2 Ready
Dival 700
Direct operated regulator with H2 compatibility.
- Design Pressure: Up to 20 bar
- Sizes: 1″ - 2″
- Classification: Fail Open (EN 334)
- Connections: ANSI 150 RF, ANSI 125 FF, PN 16/25, Threaded
H2 Ready
Dival SQD-1
Direct operated regulator for medium-low pressure distribution networks.
- Design Pressure: Up to 6 bar
- Sizes: 1½″
- Classification: Fail Open (EN 334)
- Connections: Class 150 RF, PN 16/25
H2 Ready
Dival SQD-2
Direct operated regulator with diaphragm and spring control.
- Design Pressure: Up to 6 bar
- Sizes: 2″
- Classification: Fail Open (EN 334)
- Connections: Class 150 RF, PN 16/25
H2 Ready
Dival SQD-6
Direct operated regulator for filtered gaseous fluids in distribution networks.
- Design Pressure: Up to 6 bar
- Sizes: 2″ inlet, 3″ outlet
- Classification: Fail Open (EN 334)
- Connections: Class 150 RF, PN 16/25
H2 Ready
Norval
Direct operated regulator for distribution networks.
- Design Pressure: Up to 18.9 bar
- Sizes: 1″ - 8″
- Classification: Fail Open (EN 334)
- Connections: 150 RF, PN 16
H2 Ready
Trias
Direct operated regulator for compact installations.
- Design Pressure: Up to 17 bar
- Sizes: 1-1/2″ - 2″
- Classification: Fail Open (EN 334)
- Connections: Class 150 RF, PN 16
H2 Ready
FE
Two-stage regulator with integrated OPSO.
- Design Pressure: Up to 8.6 bar
- Sizes: G 1/2″ - G 1″
- Classification: Fail Close (EN 334)
- Connections: ISO 228/1
FE515
Two-stage regulator for residential use.
- Design Pressure: Up to 5.15 bar
- Sizes: G 1/2″ - G 1″
- Classification: Fail Close (EN 334)
- Connections: ISO 228/1
H2 Ready
FEX
Two-stage regulator with OPSO and UPSO protection.
- Design Pressure: Up to 8.6 bar
- Sizes: G 1″ - G 1-1/2″
- Connections: ISO 228/1
H2 Ready
HP 100
Spring loaded direct operated regulator.
- Inlet Pressure: 1 to 20 bar
- Connections: 1" inlet, 1" or 1-1/2" outlet
- Classification: Fail Open (EN 334)
- Temperature: -20°C to +60°C
H2 Ready
NeoR
Compact regulator for residential applications.
- Design Pressure: Up to 125 psig (8.6 bar)
- Sizes: 3/4″ - 1″
- Classification: ANSI B109.4, CSA 6.18
- Connections: NPT
H2 Ready
Goval
Double diaphragm safety governor with balanced mechanism.
- Design Pressure: Up to 1 bar
- Sizes: 1/2″ - 4″
- Classification: Double Diaphragm Safety Governor
- Connections: ISO 228/1
H2 Ready
Governors STD
Double safety diaphragm governor with balanced plug.
- Design Pressure: Up to 1 bar
- Sizes: 1/2″ - 4″
- Classification: Governor (EN 88-1)
- Connections: ISO 228-1, NF E29-533/536
CSA Approved
PF 400
Governor for burner supply.
- Max. Emergency Inlet: Up to 4.5 bar
- Sizes: 3/8″ - 1/2″
- Classification: CSA 6.22A ANSI Z21.80A
- Temperature: -40°C to +65°C
H2 Ready
Ratio Governors
Double safety diaphragm governor with constant gas/air ratio.
- Design Pressure: Up to 350 mbar
- Sizes: 1/2″ - 4″
- Classification: Ratio Governor (EN 88-1)
- Connections: ISO 228, 1/4" and 1/2" Air
RCS 201
Balanced device governor for residential networks.
- Design Pressure: Up to 0.5 bar
- Sizes: 2″ (single pipe)
- Classification: Balanced Device Governor
- Connections: ISO 228/1
RCS 705
Balanced device governor for residential gas networks.
- Design Pressure: Up to 0.5 bar
- Sizes: 3/4″ and 1″
- Classification: Balanced Device Governor
- Connections: Straight, F/F
H2 Ready
Zero Governors
Zero pressure governor for low pressure gas applications.
- Design Pressure: Up to 350 mbar
- Sizes: 1/2" - 4"
- Classification: Zero Governor
- Connections: ISO 228-1, NPT
USA Market
Governor 2 PSIG
Line Gas Pressure Regulator, 2 psig Inlet
- Inlet Pressure: 7.5 mbar to 138 mbar
- Sizes: 1/2″ - 4″
- Standard: ANSI Z21.80 / CSA 6.22
USA Market
Governor Dual Cut
Two-Stage Line Gas Pressure Regulator, 10 psig Inlet
- Inlet Pressure: 207 to 689 mbar
- Sizes: 1/2″ - 4″
- Standard: ANSI Z21.80 / CSA 6.22
USA Market
Governor OPD
Regulator with Integrated Over Pressure Device, 10 psig Inlet
- Inlet Pressure: 17.4 to 689 mbar
- Sizes: 1/2″ - 4″
- Standard: ANSI Z21.80 / CSA 6.22
USA Market
Zero Governors USA
Zero Governor for Zero-Pressure Regulation
- Inlet Pressure: 19.9 to 345 mbar
- Sizes: 1/2″ - 4″
- Standard: ANSI Z21.18 / CSA 6.3
Smart
HM
Smart diaphragm meter with GSM/GPRS communication.
- Flow Range: G10, G16, G25
- Accuracy: Class 1.5
- Communication: GSM/GPRS
HM-iCON
Smart meter with iCON module and NB-IoT.
- Flow Range: G10, G16, G25
- Accuracy: Class 1.5
- Communication: NB-IoT, GPRS
SSM-iCON
Static smart meter with NB-IoT connectivity.
- Flow Range: G4
- Accuracy: Class 1.5
- Communication: GPRS, NB-IoT, RF
SSM-iCON 250
Compact smart meter with Cat-M1 connectivity.
- Flow Range: 0.007 - 7.1 m³/h
- Accuracy: Class 1 (ANSI B109.0)
- Communication: NB-IoT, Cat-M1
SSM-iCON 400
Large capacity smart meter with IoT features.
- Flow Range: 0.09 - 11.6 m³/h
- Accuracy: Class 1 (ANSI B109.6)
- Communication: NB-IoT, Cat-M1
H2 Ready
RSE/RSV
Smart diaphragm meter with integrated valve option.
- Flow Range: G1.6, G2.5, G4, G6
- Accuracy: Class 1.5
- Communication: GPRS, NB-IoT, RF
H2 Ready
MM
Mechanical diaphragm gas meter for commercial use.
- Flow Range: G10, G16, G25
- Connection: 1-1/4″, 2″, 2-1/2″
- Application: Commercial / Light Industrial
H2 Ready
RS/2001 LA
Mechanical diaphragm meter with H2 compatibility.
- Flow Range: G1.6, G2.5, G4
- Accuracy: Class 1.5
- Connection: 3/4" - 1¼" ISO 228
H2 Ready
RS 2.0 / RST 2.0
Module-ready diaphragm meter with H2 compatibility.
- Flow Range: G4, G6
- Cyclic Volume: 2.0 Liter
- Features: Temp Compensated (RST)
H2 Ready
RS/2,4
Mechanical diaphragm gas meter for residential low-pressure distribution.
- Flow Range: G4, G6
- Cyclic Volume: 2.4 Liter
- Features: Mechanical
H2 Ready
IM-TM
High-performance turbine meter for custody transfer.
- Flow Range: 8 - 6,500 m³/h
- Sizes: 2″ - 12″
- Temperature: -40°C to +65°C
H2 Ready
IM-RM
Positive displacement rotary meter for industrial use.
- Flow Range: 0.5 - 1000 m³/h
- Sizes: 1-1/2″ - 6″
- Temperature: -25°C to +55°C
H2 Ready
FioSonic
Multi-path ultrasonic meter for fiscal metering.
- Flow Range: Up to 43,700 m³/h
- Sizes: 2″ - 30″
- Pressure: Up to 153 bar(a)
H2 Ready
FioSonic Mini
Compact ultrasonic meter for distribution.
- Flow Range: Up to 991 m³/h
- Sizes: 3″ - 4″
- Pressure: Up to 20 bar
Smart
SSM-AQUO
Ultrasonic smart water meter with IoT connectivity.
- Sizes: 1/2″ - 2″
- Dynamic Range: Up to R500
- Battery Life: 13 years
Smart
SSM-AQUO EV
Smart water meter with integrated electronic valve.
- Dynamic Range: R500
- Valve: Integrated Electrovalve
- Design Life: 13+ years
Smart
Modus
PTZ electronic volume corrector with Modbus.
- Correction: PTZ (up to 2 channels)
- Certification: MID, ATEX Zone 0
- Communication: Modbus / CTR
Smart
Modus Slim2
Compact PTZ volume corrector MID certified.
- Correction: PTZ (Compact)
- Certification: MID, ATEX Zone 0
- Communication: UNI TS 11291-3
Smart
Modus Mini
MID certified single-channel Electronic Volume Converter with embedded NB-IoT / Cat-M1 modem for ATEX Zone 1 areas.
- Correction: PTZ (single channel)
- Communication: DLMS/COSEM, NB-IoT / Cat-M1
- Enclosure: IP66
H2 Ready
Floating Ball Valves
Side-entry bolted floating ball valves for gas isolation.
- Size: 1/2″ - 36″
- Pressure: Up to 420 bar
- Type: Floating
H2 Ready
Trunnion Ball Valves
Trunnion mounted ball valves up to Class 2500.
- Size: Up to 60″
- Pressure: Up to 1035 bar (API)
- Type: Trunnion
H2 Ready
Deltaflux
Control ball valve for precise flow management.
- Size: 2″ - 48″
- Pressure: Class 150 - 2500
- Type: Control
BF 31
Butterfly valve for gas distribution systems.
- Size: 12″ - 24″
- Pressure: Up to 19 bar
BF 32
Compact butterfly valve with hermetic seal.
- Size: 2″ - 10″
- Pressure: Up to 19 bar
H2 Ready
Dilock
Quick gas flow interception safety device for medium and low-pressure networks.
- Size: Up to 2″
- Pressure: Up to 20 bar
- Connections: ANSI 150, PN 16
HBC 975
High pressure slam shut valve up to 102 bar.
- Size: 4″ - 12″
- Pressure: Up to 102 bar
- Connections: ANSI 150/300/600, PN 16
SBC 782
Slam shut valve for industrial applications.
- Size: 1″ - 10″
- Pressure: Up to 102 bar
- Response: < 1 sec
SBC 187
Ultra high-pressure safety device for transmission systems.
- Size: 1″
- Pressure: Up to 250 bar
- Connections: ANSI 1500
SBC Mini
Compact ultra high-pressure safety device for transmission systems.
- Size: 1″
- Pressure: Up to 250 bar
- Connections: ANSI 1500, NPT
H2 Ready
SCN
Compact safety device for medium and low-pressure gas distribution.
- Size: 1″ - 8″
- Pressure: Up to 16 bar
- Connections: ANSI 150, PN 16
SSX 176
High performance slam shut valve.
- Size: 1″ - 6″
- Pressure: Up to 102 bar
- Reset: Manual
PVS 782
Pilot operated relief valve up to 102 bar.
- Size: Up to 8″
- Pressure: Up to 102 bar
- Setting Range: 1.5 - 74 bar
PVS 803
Pilot operated relief valve for high pressure.
- Size: Up to 6″
- Pressure: Up to 102 bar
- Setting Range: 1.5 - 74 bar
H2 Ready
VS/AM 58
Direct operated relief valve for distribution.
- Size: 1″
- Pressure: Up to 100 bar
- Type: Direct Operated
H2 Ready
VS/AM 65
Direct operated relief valve for safety systems.
- Size: 1″
- Pressure: Up to 20 bar
- Type: Direct Operated
Reflux 919
Control valve for precise flow regulation.
- Size: Up to 10″
- Pressure: Up to 100 bar
- Type: Diaphragm
Sincroflux
Regulating valve for flow management.
- Size: Up to 10″
- Pressure: Up to 102 bar
- Type: Regulating
VLM
Manually operated bypass and throttling valve for distribution.
- Size: Up to 8″
- Pressure: Up to 100 bar
- Type: Bypass
H2 Ready
HFA-HFB
Dry gas filters for high pressure applications.
- Sizes: Up to 12″
- Filtration: 5 - 50 micron
- Pressure: Up to 100 bar
Filters for Low Pressure
Filters for low pressure gas distribution.
- Sizes: Up to 6″
- Filtration: 5 and 50 micron
- Pressure: Up to 10 bar
Non-Radioactive
Flowatch 3i
Non-radioactive multiphase flow meter.
- Sizes: 0.5″+
- Pressure: Up to 345 bar
- GVF: 0-92%
High Speed
Flowatch HS
High-speed multiphase flow meter.
- Sizes: 1.3″+
- Pressure: Up to 345 bar
- GVF: 0-98%
All Flow Regimes
Totem
Modular non-intrusive inline measurement.
- Sizes: 2″ - 14″
- Pressure: Up to 345 bar
- GVF: 0-100%
Microwave
WLR Meter
Water content measurement device.
- Sizes: 2″ - 14″
- Pressure: Up to 345 bar
- WLR: 0-100%
Wetgas
Xtreme S
Dedicated wetgas metering solution.
- Sizes: 2″ - 14″
- Pressure: Up to 345 bar
- GVF: 90-100%
Systems
Pressure Reducing Stations
Complete skid-mounted or cabinet stations.
- Configuration: Skid/Cabinet
Complete
City Gate Stations
Complete metering and regulation stations.
- Function: Metering & Regulation
- Type: Integrated System
Need Technical Assistance?
Our engineers are ready to help you select the right products for your application.